Troubleshooting - Brivis

If at any point your Brivis system doesn’t start we recommend a manual reset. Try resetting your heater through the controller. Refer to information provided on this page that is relevant to your controller.

If this doesn’t work, a power reset may resolve the issue. This is done by turning the power off to at the the power point to your unit. Or alternatively, it may be easier to turn the power off to your house (at the mains). Leave for a minute and then turn back on.

Brivis client troubleshooting guide

Work through the symptom that matches your issue before calling for service. Most problems can be resolved without a technician visit.

Check these first

  • Check the networker display isn't blank — if blank, the power supply to the heater may not be switched on or connected correctly.
  • Check the circuit breaker in your meter box hasn't tripped — reset it if so. If it keeps tripping, call us.
  • Make sure the set temperature is higher than the current room temperature — the heater won't run if the room is already warm enough.
  • Check that a programmed timer hasn't turned the heater off.
  • Check the gas supply is on at the meter and at the appliance gas cock near the heater.

Try resetting

  • If RESET appears beside Key 4, press it to restart the heater.
  • If RESET isn't showing, press Fn then Key 1 to display the error and RESET option.
  • If that doesn't help, turn the networker off, wait 2 minutes, then turn back on.
  • Last resort: switch off the power point near the heater, wait 1 minute, then switch it back on.

Check airflow — the most common cause

  • Make sure enough floor or ceiling vents are open — too many closed vents cause the heater to overheat and shut down.
  • Check all register baffles are fully open and not blocked by furniture or rugs.
  • Check the return air filter — a clogged filter is the most frequent cause of shutdown. Clean or replace it.
  • Make sure nothing is blocking the return air grille in the wall or ceiling.

Check the flue

  • Make sure the flue terminal is clear of leaves, debris, or bird nests.
  • Ensure the air intake at the burner end of the heater is also clear.
  • SP6 models: check the condensate tube for blockages.
ℹ If the display shows a spanner symbol or error code, see the Error Codes section below.

Check gas supply

  • Confirm gas is on at the meter and at the appliance gas cock near the heater.
  • Check that other gas appliances (cooker, hot water) are working — if they're out too, the issue is with your gas supply, not the heater.
  • LPG users: check the cylinders have gas and the cylinder valve is open.
  • Contact your gas provider if you suspect a supply interruption in the street.

Reset the heater

  • Press Key 4 (RESET) after confirming gas supply to attempt a restart.
  • If the error keeps returning after reset and gas is confirmed on, a service call is required.

Check the mode

  • Check Fan Only mode hasn't been selected (Key 1 on the networker) — in this mode the fan runs without heating.
  • Confirm the networker is set to Heating mode.

Check airflow

  • Make sure sufficient vents are open — too few can prevent the heater from firing.
  • Clean the return air filter and grille.
  • Check that ducting hasn't been crushed or collapsed — if so, contact us.

Likely cause

  • Whistling is almost always caused by a dirty or blocked return air filter or grille — clean the filter and ensure the grille is unobstructed.
  • If the noise persists after cleaning, ducting or a register may be partially blocked — contact us.

What to check

  • If zoning is installed, check that the zone for that area is enabled on the networker.
  • If no zoning is installed, this is likely an installation issue — contact us.

What this means

  • The padlock means the networker has been locked using the PIN feature.
  • To unlock: press Fn then Key 2, then enter your 4-digit PIN (factory default is 1111).
  • If the PIN has been changed and you don't know it, contact us.

Check these first

  • The unit has a 3-minute protection delay — it cannot restart within 3 minutes of being turned off. Wait and try again.
  • Check the power supply and that the circuit breaker hasn't tripped.
  • Check if a timer has turned the unit off — press power on the networker or remote to override.
  • Confirm the networker is set to Cooling mode (not Heating or Fan Only).
  • A flashing snowman symbol on the display is normal — it means the unit is in a short startup delay.

Check mode and settings

  • Confirm the unit is in COOL mode — Fan Only circulates air without cooling.
  • The set temperature must be lower than the current room temperature.
  • On very hot days it may take time to bring the room down — this is normal.

Check for restrictions

  • Nothing should be blocking the front of the indoor unit — move curtains, blinds, or furniture away.
  • Clean the air filter — this should be done every 2 weeks during the cooling season.
  • Make sure the outdoor unit's air inlet and outlet are not blocked.
  • Close all doors and windows while running.
  • Close blinds during periods of direct sun to reduce heat load.
ℹ If the unit switches from Cool to Fan mode on its own, it is preventing frost from forming — it will resume cooling automatically once the temperature rises.

Normal sounds — nothing to worry about

  • Water flowing or hissing from the indoor unit — refrigerant moving through the system, completely normal.
  • Low hiss at startup, shutdown, or during defrost — refrigerant stopping or changing direction, normal.
  • Outdoor fan speed changes — the unit adjusts speed automatically to optimise performance.

Sounds that need attention

  • Loud banging, grinding, or rattling — turn the unit off and call us.
  • Any burning smell — turn the unit off immediately and call us.

Likely cause

  • The unit may be absorbing odours from the environment (furniture, cooking, smoke) — common and not a fault.
  • Check the air filter — if mouldy, clean or replace it.
  • Burning smell: turn the unit off immediately and call us.

Check these first

  • Check the power supply isolating switch is on — usually located near the unit on the roof or in the ceiling.
  • Check the circuit breaker hasn't tripped — reset if so.
  • If the Networker display shows the time and room temperature but not the word "COOLER", the unit has lost communication with the controller — a service call is required.
  • Check a timer hasn't automatically turned the unit off.

Check ventilation — critical for evaporative cooling

  • Evaporative cooling requires doors and/or windows to be open so hot air can escape — ensure you have sufficient openings.
  • Works best on hot, dry days. On humid days, cooling effectiveness is naturally reduced.
  • On humid days, try turning the pump off and running on fan only.

Check the unit itself

  • Check the filter pads are clean and undamaged — old or deteriorated pads lose their ability to cool the air.
  • Ensure the pump is running and water is being distributed evenly across the pads.
  • Check the water supply is turned on and the tank is filling correctly.

This is often completely normal

  • Advance & Promina series: water is periodically dumped (roughly every 20 pump cycles) to flush salts — this is the Running Refresh and is normal.
  • AD series: a small continuous flow from the drain outlet is normal — this is the bleed off method for water quality control.
  • Contour series: these use an AquaSave system and should not dump water — if water is coming out, contact us.

What to check

  • Make sure vents are aimed across the room, not directed at the floor.
  • Ensure enough doors and windows are open — trapped moisture causes condensation.
  • On humid days, turn the pump off and run on fan only.

Likely cause

  • New cooling pads can produce a mild smell while settling in — normal, will dissipate quickly as the pads are flushed.
  • A persistent musty smell usually means the unit needs a service — pads and tank need cleaning.

What to check

  • Most likely an installation issue — contact us in the first instance.
  • Note: evaporative cooling cannot share ductwork with ducted gas heating. Each system needs its own dedicated ductwork.

When the spanner symbol appears, press Fn then Key 1 to display the error message. Note the code below and follow the steps shown.

Code What it means What to do
40 / 41 / 42 / 43 Overheat — heater is getting too hot Open more floor or ceiling vents. Check all register baffles are fully open. Clean the return air filter and grille.
46 / 47 / 55 Ignition failure — heater failed to light Check gas is on at the meter and appliance. Check other gas appliances are working. If gas is confirmed on, a service call is required.
50 Lockout after four failed ignition attempts Press Key 4 (RESET) to restart. Confirm gas supply is on. If error returns after reset with gas confirmed, the heater needs a service.
53 Lockout — multiple overheat events Open more vents. Check registers and baffles are fully open. Clean the return air filter. Reset the heater — if error 53 returns, contact your installer.
56 Pressure switch lockout — flue restriction or gusty wind Check the flue pipe for blockages or debris. SP6 models: also check the condensate piping. Gusty wind can trigger this — reset after conditions settle.
Other Electronic control module fault Switch off the power point near the heater, wait 1 minute, then switch back on. If the error persists, contact us.
ℹ To clear the spanner icon after resolving an issue: press Key 4 (RESET) on the networker. If RESET isn't visible, press Fn then Key 1 first.

⚠ Turn the unit off immediately and call us if you notice:

  • A burning smell coming from any part of the system
  • The power cord is warm, damaged, or melted
  • Loud banging, grinding, or abnormal sounds
  • A circuit breaker that trips every time the unit runs
  • Water leaking from the indoor unit when humidity is low
  • The unit has been exposed to flooding
📞

Still having issues? Call Frazer Air on (03) 9465 3533 — we're your first point of contact for all Brivis service and support. Have your model number and a description of the issue ready.

Resource Videos

PROGRAMMING YOUR BRIVIS NETWORKER

This video demonstrated how to setup your Brivis networker wall control for automatic operation. This means you can customise your system to your needs.

SERVICE NOTIFICATION ON BRIVIS NETWORKER

After 1500 hours fan run time approximately two and a half years a service notification message will scroll across the top of the screen with a spanner icon ...

HOW TO RESET YOUR BRIVIS NETWORKER

If you are having problems starting your Brivis heater or cooler unit, resetting your wall controller may resolve your issue. In this tutorial I will show yo...

RESET MANUAL WALL CONTROLLER

If your manual wall controllers display is either not displaying or fading this video will guide you on how to change your batteries on the manual wall controller

Brivis Touch Add-on Cooling Instruction Video

BRIVIS TOUCH INSTRUCTION VIDEO

Brivis Touch Evaporative Cooling Instructional Video

 

Service & Warranty

Brivis Climate System Warranty - Brivis Australia

Contact Frazer Air on 9465 3533 for all your servicing needs

Brivis Service Advantage offers an optional 4 years parts and labour extended warranty in addition to the standard 5 year Brivis parts and labour warranty, and is available when you elect to participate in the Brivis Service Advantage program. (Excludes CC3 Series gas ducted heaters. See Terms and Conditions